mirror of
https://github.com/kevinveenbirkenbach/computer-playbook.git
synced 2026-11-06 10:59:59 +00:00
Since the role moved to n8n 2 (2.42.3 on 2026-10-05, now 2.44.0),
POST /rest/workflows/:id/run accepts a manual run only with a trigger to
start from or a destination node; any other key, `workflowData` among them,
is dropped. The LiteLLM gateway test still sent only `workflowData`, so every
attempt failed with HTTP 400 "To run the workflow manually, specify either a
trigger to start from or a destination node." (PR #912, run 38455633497,
job 115523214958). On main the test sat behind the MCP provisioning failure of
n8n#0 that e4078c05fd fixed, so the next main run would have hit it.
The test now runs the stored probe workflow from its manual trigger.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>